Merck
CN
  • Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of bisoprolol in human plasma.

Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of bisoprolol in human plasma.

Journal of chromatography. A (2015-11-18)
Joanna Giebułtowicz, Grzegorz Kojro, Katarzyna Buś-Kwaśnik, Piotr J Rudzki, Ryszard Marszałek, Andrzej Leś, Piotr Wroczyński
ABSTRACT

Cloud-point extraction (CPE) draws increasing interest in a number of analytical fields including bioanalysis, but combining CPE and LC-MS with electrospray ionization (ESI) in the determination of drugs in biological fluids such as plasma, serum or blood has not been reported so far. Bisoprolol was determined in human plasma by CPE using Trition X-114 as a surfactant and metoprolol as the internal standard. NaOH concentration, temperature and Trition X-114 concentration were optimized. All analyses were performed using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). All validation experiments met international acceptance criteria and no significant matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples and appropriate statistical tests. The determination of bisoprolol concentration in human plasma in the range 1.0-70ngmL(-1) by the CPE method leads to the results which are equivalent to those obtained by the widely used liquid-liquid extraction method. The results revealed that a structural analogue may be an appropriate internal standard when CPE is used as the extraction technique. CPE offers significant practical advantages over the classical extraction methods, including a positive impact on the environment, therefore its wider application in future pharmacokinetic studies is justifiable.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Methanol solution, contains 0.50 % (v/v) triethylamine
Sigma-Aldrich
Methanol, purification grade, 99.8%
Sigma-Aldrich
Methanol, NMR reference standard
Sigma-Aldrich
Acetonitrile, Preparateur, ≥99.9% (GC), One-time steel-plastic (SP) drum
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis