grade
technical
Quality Level
form
crystals
reaction suitability
core: molybdenum, reagent type: catalyst, reagent type: oxidant
mp
98 °C (dec.) (lit.)
density
2.83 g/mL at 25 °C (lit.)
SMILES string
O.[Na+].[Na+].[Na+].[O-][Mo](=O)(=O)O[Mo](=O)(=O)O[Mo](=O)(=O)O[Mo](=O)(=O)OP(=O)(O[Mo](=O)(=O)O[Mo](=O)(=O)O[Mo](=O)(=O)O[Mo]([O-])(=O)=O)O[Mo](=O)(=O)O[Mo](=O)(=O)O[Mo](=O)(=O)O[Mo]([O-])(=O)=O
InChI
1S/12Mo.3Na.H3O4P.H2O.36O/c;;;;;;;;;;;;;;;1-5(2,3)4;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;/h;;;;;;;;;;;;;;;(H3,1,2,3,4);1H2;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;/q;;;;;;;;;6*+1;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;3*-1/p-3
InChI key
GVSXYXXCIUVHQT-UHFFFAOYSA-K
Application
Reactant for synthesis of:
Reactant for:
Used for:
- Supramolecular hydrogen-bonded Archimedean cages with encapsulated organic and inorganic species
Reactant for:
- Temperature programmed reduction and hydrogen-isotope exchange
- Passivation of stainless steel
Used for:
- Plastic membrane electrodes for determination of flavoxate hydrochloride and cyclopentolate hydrochloride
- Investigations of catalyst load role on transesterification of di-Me carbonate and phenol
- Cocatalyst for methanol carbonylation
存储类别
11 - Combustible Solids
wgk
WGK 2
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
Hajime Katano et al.
Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 27(10), 1043-1047 (2011-10-12)
New appropriate reaction system was found for spectrophotometric determination of phosphate anion. This spectrophotometric method is based on the color development due to the formation of yellow molybdophosphate anion in acidic ethylene glycol-water (EG-W) mixed solution containing Mo(VI) species. The
Juan Feng et al.
Analytical biochemistry, 409(1), 144-149 (2010-10-26)
The classical malachite green (MLG) assay of phosphate, which added MLG after molybdate to the acidified reaction solutions of phosphate, tolerated interference from papaverine, sildenafil, and some similar hydrophobic amines. Resonance Rayleigh scattering signals, the alleviation of interference by poly(vinyl
Andrey V Bulatov et al.
Talanta, 96, 62-67 (2012-07-24)
Simple, rapid and fully automated methods for the manual and automated spectrophotometric determination of epinephrine have been developed by using schemes of stepwise injection (SWIA) and sequential injection analysis (SIA) implemented in the same manifold. The determination is based on
全球贸易项目编号
| 货号 | GTIN |
|---|---|
| 79558-100G | 04061833381427 |