登录 查看组织和合同定价。
选择尺寸
变更视图
关于此项目
NACRES:
NA.32
UNSPSC Code:
41116158
Gene information:
human ... SERPINE1(5054)
Input:
sample type cell culture supernatant(s)
sample type serum
sample type plasma
sample type serum
sample type plasma
Species reactivity:
human
Storage temp.:
−20°C
Shipped in:
wet ice
species reactivity
human
packaging
kit of 96 wells (12 strips x 8 wells)
technique(s)
ELISA: suitable, capture ELISA: suitable
input
sample type cell culture supernatant(s)
sample type serum
sample type plasma
assay range
inter-assay cv: <12%
intra-assay cv: <10%
sensitivity: 35 pg/mL
standard curve range: 0.102-25 ng/mL
detection method
colorimetric
shipped in
wet ice
storage temp.
−20°C
Gene Information
human ... SERPINE1(5054)
General description
The Human PAI-1 (plasminogen activator inhibitor-1) ELISA (enzyme-linked immunosorbent assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human PAI-1 in serum, plasma, cell culture supernatants. PAI-1 is 45kDa serine proteinase inhibitor. It inhibits plasmogen activator and affects the fibrinolytic process, as a result of which it leads to thrombosis. Reduced fibrinolysis is observed in ischemic heart disease. While elevated PAI-1 levels are noticed in myocardial infarction. PAI-1 is associated with various physiological processes including wound healing, sepsis, insulin resistance, obesity, atherosclerosis, tumor angiogenesis, bone remodeling, asthma, rheumatoid arthritis, glomerulonephritis and chronic stress.
Immunogen
Recombinant Human PAI-I
Application
请参考Protocol了解详情。
Other Notes
A sample Certificate of Analysis is available for this product.
Please type the word sample in the text box provided for lot number.
Please type the word sample in the text box provided for lot number.
signalword
Warning
hcodes
pcodes
Hazard Classifications
Met. Corr. 1
存储类别
10 - Combustible liquids
法规信息
低风险生物材料
常规特殊物品
此项目有
Brain Edema XI: Proceedings of the 11th International Symposium, 277-277 (1999)
Pleiotropic functions of plasminogen activator inhibitor-1
Lijnen, HR
Journal of Thrombosis and Haemostasis, 3(1), 35-45 (2005)
María Paniagua-Sancho et al.
American journal of nephrology, 52(9), 714-724 (2021-09-15)
Acute kidney injury (AKI) is a threatening, multiaetiological syndrome encompassing a variety of forms and damage patterns. AKI lacks sufficiently specific diagnostic tools to evaluate the distinct combination of pathophysiological events underlying each case, which limits personalized and optimized handling.
全球贸易项目编号
| 货号 | GTIN |
|---|---|
| RAB0429-1KT | 04061834962526 |