Merck
CN
All Photos(1)

Documents

MPGP002A1

Milli-Q

Millipak® Filter

0.22 μm membrane filter for particulate and bacteria-free water at the point of dispense for the Milli-Q® IQ, IX and EQ 7 series water purification systems.

Sign Into View Organizational & Contract Pricing

Synonym(s):
Millipak® 0.22 μm filter
eCl@ss:
33050190

material

polyethersulfone filter

Quality Level

packaging

pkg of 1 unit

manufacturer/tradename

Millipak®

pore size

0.22 μm pore size

compatibility

for use with Milli-Q® EQ 7000
for use with Milli-Q® EQ 7008
for use with Milli-Q® EQ 7016
for use with Milli-Q® IX 7003
for use with Milli-Q® IX 7005
for use with Milli-Q® IX 7010
for use with Milli-Q® IX 7015
for use with Milli-Q® IQ 7000
for use with Milli-Q® IQ 7003
for use with Milli-Q® IQ 7005
for use with Milli-Q® IQ 7010
for use with Milli-Q® IQ 7015

shipped in

ambient

Looking for similar products? Visit Product Comparison Guide

Related Categories

General description

The Millipak® 0.22μm hydrophilic membrane filter is intended to produce particulate-free and bacteria-free water at the point of dispense of the Milli-Q® IQ 7000 system, Milli-Q® IQ 7003/05/10/15, Milli-Q® IX 7003/05/10/15 and Milli-Q® EQ 7000/08/16 water purification systems..
The filter is designed with a 0.22μm PES (polyethersulfone) asymmetric membrane filter heat-sealed on a styrene-acrylonitrile housing that serves to minimize organic and inorganic extractable release.

Application

Pure and Ultrapure water produced by a Millipak® 0.22 μm filter is suitable for many different laboratory applications, including microplastics research, nanoparticle studies, food analyses and HPLC analyses.

Features and Benefits

  • Each Millipak® 0.22μm filter is individually tested, hermetically sealed and delivered with a Certificate of Quality.
  • Validated to deliver bacteria-free water (<0.01cfu/mL when installed and used in a laminar flow hood).
  • Carefree maintenance: Easily installed and replaced.
  • Redesigned bottom-tip for a secured installation of the protection bell.
  • Validated to deliver particulate-free water (no particles with size >0.22 μm)
  • e-Sure tag for RFID connection with E-POD® or Q-POD® dispenser enables full traceability (data management) and automatic consumable status monitoring on the POD’s touchscreen interface.

Other Notes

Directions for Use

  • Organism Retention: Microorganisms
  • Mode of Action: Filtering
  • Application: General laboratory analysis
  • Intended Use: Water purification
  • Instructions for Use: This item provides water filtered through 0.22 μm sterilizing-grade membranes. Refer to the system equipment user guide section "Using the System" (available on USB key in the system box).
  • Storage Statement: Store in a dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Legal Information

E-POD is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPAK is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany
Q-POD is a registered trademark of Merck KGaA, Darmstadt, Germany

also commonly purchased with this product

Product No.
Description
Pricing

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

  1. How frequently do the various consumables need to be changed?

    The frequency that consumables must be changed depends on the system's usage (treated water volume) and on the consumables themselves (time of usage). In order to ensure the quality of water and your results, the consumables should be replaced when the system alerts you.

  2. What is the consumables delivery time?

    Refer to the consumable's Product page for a first estimation of its expected delivery time and contact customer service for more information.

  3. How are consumables changed?

    To help you to change your system's consumables, several video tutorials are available on our YouTube channel: Milli-Q®System Care Tutorials. For high-flow systems, please keep in mind that all consumable changes must be approved by a 3-digit code that only the person in charge of the system knows.

  4. What is the shelf life for Filter?

    The shelf life is 2 years for all consumables kept in the recommended storage conditions (temperatures from 5 to 30°C; humidity between 10 and 80%). Contact your local representative for more information.

  5. Can I arrange to have my consumables automatically ordered and delivered once a year?

    It's possible to place only one consumable order per year with a specific contract called "Consumable Supply Agreement (CSA)" For further information, contact your local representative or sales contact.

  6. Where can I find data sheets, Certificates of Origin, Certificates of Analysis, and Certificates of Quality?

    Documents and certificates are available in the "Documentation" section on this page. Do not hesitate to contact us if you require further information.

  7. What steps are you taking towards improved sustainability?

    Sustainability is at the heart of our innovations. From reducing water and energy consumption, to minimizing plastic and chemical waste, our dedicated water system engineers are constantly working on new ways to reduce the ecological footprint of our products to better support the sustainability goals we’re all striving towards. For more information, we invite you to review the following brochure and infographic which highlight our efforts and achievements: link. Do not hesitate to contact your local representative for further information.

  8. How can I know which consumables can be used with my system?

    To know which consumables can be used on your system, you can see in the user manual of you system or see it on the following webpage of consumables. All the consumables for each system are indicated.

  9. If I have a final filter that I use only occasionally (e.g., Biopak®) and have another filter (e.g. Millipak®) that I most of the time, can I keep the 'occasional-use' filter for use again at a later time?

    It is not possible to re-use a filter that has been used and then removed because air intake during replacement creates an airlock and blocks water passing through the filter. If you regularly need two different filters, we recommend using two POD dispensers.

  10. Can consumables be opened and refilled?

    Unfortunately, this is not possible because of safety issues and the need to guarantee the quality of consumables and their interior purification components. Our consumables are manufactured in an ISO 9001-certified facility France in agreement with high quality standards.

Zehua Yan et al.
Journal of hazardous materials, 384, 121489-121489 (2019-11-11)
Concerns have been raised regarding the ingestion of microplastics (MPs) by numerous organisms including humans. However, no efficient and standardized methods are available for extracting MPs from feces. In this study, we introduce a novel approach with high digestion efficiency

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service